Return to the thumbnail page Display/hide file information See previous file See next file

9,13 & 26W PL

9,13 & 26W PL

Click to view full size image

Found in the recycling bin, there is more if anyone else needs any

imagejpeg_0(4).jpg imagejpeg_0(5).jpg 20180806_160112.jpg 20150613_233309.jpg

File information

File information

Download: Download this File
Filename:20180806_160112.jpg
Album name:Alights / CFL
Keywords:Lamps
File Size:393 KB
Date added:Aug 07, 2018
Dimensions:1848 x 2464 pixels
Displayed:86 times
Date Time:2018:08:06 16:01:12
DateTime Original:2018:08:06 16:01:12
Exposure Bias:0 EV
Exposure Time:1/120 sec
FNumber:f 1.7
Flash:No Flash
Focal length:4.2 mm
ISO:100
Make:samsung
Model:SAMSUNG-SM-G891A
Software:G891AUCU3CRE7
White Balance:0
URL:https://www.lighting-gallery.net/gallery/displayimage.php?pos=-149440
Favorites:Add to Favorites
Comments
fluorescent lover 40
Sr. Member
****
Offline

Gender: Male
View Posts
View Gallery

Lights are awesome! :)


View Profile Personal Message (Offline)
Aug 07, 2018 at 08:51 PM Author: fluorescent lover 40
Nice! Good quality stuff here!

Power provider: Southern California Edison (SCE)

- Lamp and fixture collector
- Switch and receptacle collector.
- Here to work, here to serve, here to save.

RyanF40T12
Hero Member
*****
Offline

Gender: Male
View Posts
View Gallery

View Profile Personal Message (Offline)
Aug 07, 2018 at 09:33 PM Author: RyanF40T12
My church buildings use a lot of these. I don't like them because of the electronic ballasts that fail so often.

The more you hate the LED movement, the stronger it becomes.

nicksfans
Hero Member
*****
Offline

Gender: Male
View Posts
View Gallery

Down with lamp bans!


GoL the.baus.of.all.bauses UCDl2EWWZc9h1IZXcfGU9OZA nicksfans
View Profile Personal Message (Offline)
Aug 08, 2018 at 12:43 AM Author: nicksfans
The 2-pin ones are preheat and the chokes seem to be very reliable.

I like my lamps thick, my ballasts heavy, and my fixtures tough.

My Gallery
Instagram
YouTube

streetlight98
Sr. Member
****
Offline

Gender: Male
View Posts
View Gallery

Mike McCann


GoL Mike McCann 88219189@N04/albums
View Profile WWW Personal Message (Offline)
Aug 08, 2018 at 07:03 PM Author: streetlight98
Yeah you virtually can't kill a choke, be it fluorescent or HID. Stuck starters are probably the only thing that could unless the wrong lamp was put in but if it's a drastic enough difference in wattage aren't the bases usually different? Yeah the electronic PL ballasts don't seem very reliable. Only nice thing about them is that they're all programmed start instead of IS so the lamps don't take that extra beating but the electronic ones run HOT! There's some 32W PL cans in the bathrooms at Aerovox where I'm working on a grow-op and those lamps run as hot as incandescents and the plastic bases are all brown from heat. A bunch of bad ballasts too and they're all a mix of brands so looks like a bunch have been replaced since the building opened in 2000. Every 2x2 u-bend and 2x4 F32T8 troffer I've removed has had the original 277V (only) electronic ballast though! Those are all Advance and Sylvania full size cases. The bathrooms also have strip lights recessed in the ceiling with an eggcrate tray along the wall over the toilets and a couple bad ballasts in those. Howard Lighting 4-lamp F32 and Triad 2-lamp F25T8 to be exact. Those are the only two failed linear ballasts out of over 100 I've seen in the building other than the F54HO highbays, which are not original (installed around 2010).

Please check out my newly-updated website! McCann Lighting Company is where my street light collection is displayed in detail.

Alights
Full Member
***
Offline

View Posts
View Gallery

USA (120V 60HZ)


View Profile Personal Message (Offline)
Aug 08, 2018 at 09:03 PM Author: Alights
Yep the 13w and 18w have different bases and 26-42W is the same, there is 2x13W 2x18w 2x26w and 2x42W ballasts, I've noticed they last for a long time when only running 1 lamp
As for preheat chokes..yeah I've only changed a few that were bad and they were 277V 13W over 5 years, the series 2x13w only changed 2 they seem prone to eat lamps when they fail, a manager told me they changed lamps on a fixture every week!