Return to the thumbnail page Display/hide file information See previous file See next file

Old GE 40 watt bulb

Old GE 40 watt bulb

Click to view full size image

Fluorescent lover 40, this is for you.

20181109_131323.jpg 20181109_150045.jpg 20180830_104251.jpg 20180726_105610.jpg

Light Information

Light Information

Manufacturer:GE
Lamp
Lamp Type:40 watt incandescent
Base:Screw base
Shape/Finish:A19
Fixture
Fixture Type:Glass drum
Ballast Type:Itself
Socket Type:E26
Electrical
Wattage:40
Voltage:120

File information

File information

Download: Download this File
Filename:20180830_104251.jpg
Album name:Fluorescent05 / Incandescent
Keywords:Lamps
File Size:259 KB
Date added:Aug 30, 2018
Dimensions:2464 x 1386 pixels
Displayed:94 times
Date Time:2018:08:30 10:42:51
DateTime Original:2018:08:30 10:42:51
Exposure Bias:0 EV
Exposure Time:1/12 sec
FNumber:f 1.7
Flash:No Flash
Focal length:4.25 mm
ISO:250
Make:samsung
Model:SM-G950U
Software:G950USQU5CRG3
White Balance:0
URL:https://www.lighting-gallery.net/gallery/displayimage.php?pos=-150279
Favorites:Add to Favorites
Comments
Fluorescent05
Full Member
***
Offline

Gender: Male
Posts: 210
View Gallery

Zack


View Profile Personal Message (Offline)
Aug 30, 2018 at 09:08 AM Author: Fluorescent05
This is from that glass drum light.

Don't be fooLED, T8 IS the worst thing to do to a magnetic T12 fixture.

fluorescent lover 40
Full Member
***
Offline

Gender: Male
Posts: 219
View Gallery

Lights are awesome! :)


View Profile Personal Message (Offline)
Aug 30, 2018 at 11:19 AM Author: fluorescent lover 40
Late 60's to early 70's vintage.

Power provider: Southern California Edison (SCE)

-Date decoder of some US lamps 1960-present.
-Switch and receptacle collector.
-I'll save what I can! Smiley

Fluorescent05
Full Member
***
Offline

Gender: Male
Posts: 210
View Gallery

Zack


View Profile Personal Message (Offline)
Aug 30, 2018 at 11:22 AM Author: Fluorescent05
Awesome! Nice old bulb!

Don't be fooLED, T8 IS the worst thing to do to a magnetic T12 fixture.

jercar954
Newbie
*
Offline

Gender: Male
Posts: 33
View Gallery


View Profile Personal Message (Offline)
Aug 30, 2018 at 07:03 PM Author: jercar954
Nice find! A true inside frost and I'll bet i has a C-9 filament mount.

Preheat and T-12 fluorescents forever! Down with LED's and instant start T-8 fluorescents.

jercar954
Newbie
*
Offline

Gender: Male
Posts: 33
View Gallery


View Profile Personal Message (Offline)
Aug 30, 2018 at 07:03 PM Author: jercar954
Nice find! A true inside frost and I'll bet i has a C-9 filament mount.

Preheat and T-12 fluorescents forever! Down with LED's and instant start T-8 fluorescents.

Fluorescent05
Full Member
***
Offline

Gender: Male
Posts: 210
View Gallery

Zack


View Profile Personal Message (Offline)
Aug 30, 2018 at 08:03 PM Author: Fluorescent05
There is another one of these in that weird 1970s fixture I posted. What does inside frost mean?

Don't be fooLED, T8 IS the worst thing to do to a magnetic T12 fixture.

jercar954
Newbie
*
Offline

Gender: Male
Posts: 33
View Gallery


View Profile Personal Message (Offline)
Aug 31, 2018 at 02:26 PM Author: jercar954
Inside frost actually is the inside of the lamp is acid etched to provide a translucent glass envelope. This was replaced in the 80s with a light, silica coating.

Preheat and T-12 fluorescents forever! Down with LED's and instant start T-8 fluorescents.

Fluorescent05
Full Member
***
Offline

Gender: Male
Posts: 210
View Gallery

Zack


View Profile Personal Message (Offline)
Aug 31, 2018 at 07:45 PM Author: Fluorescent05
Is that why the lamps glow only in the middle and appear dark on the outside?

Don't be fooLED, T8 IS the worst thing to do to a magnetic T12 fixture.

jercar954
Newbie
*
Offline

Gender: Male
Posts: 33
View Gallery


View Profile Personal Message (Offline)
Aug 31, 2018 at 09:44 PM Author: jercar954
The darkening is caused by the evaporation of the filament condensing on the inside walls of the glass bulb.

Preheat and T-12 fluorescents forever! Down with LED's and instant start T-8 fluorescents.

Fluorescent05
Full Member
***
Offline

Gender: Male
Posts: 210
View Gallery

Zack


View Profile Personal Message (Offline)
Sep 01, 2018 at 09:28 PM Author: Fluorescent05
Is that why the part that was positioned up is blackest?

Don't be fooLED, T8 IS the worst thing to do to a magnetic T12 fixture.

jercar954
Newbie
*
Offline

Gender: Male
Posts: 33
View Gallery


View Profile Personal Message (Offline)
Sep 02, 2018 at 01:06 PM Author: jercar954
That's correct. That's why you see these blacken on the top if burned in a table lamp and blackened around the neck if burned base up.

Preheat and T-12 fluorescents forever! Down with LED's and instant start T-8 fluorescents.

nogden
Sr. Member
****
Offline

Gender: Male
Posts: 382
View Gallery

Nelson Ogden


View Profile Personal Message (Offline)
Sep 02, 2018 at 06:50 PM Author: nogden
Nice! I think this is my favorite GE etch style.
rjluna2
Sr. Member
****
Offline

Gender: Male
Posts: 309
View Gallery

Robert


GoL
View Profile Personal Message (Offline)
Sep 03, 2018 at 08:34 AM Author: rjluna2
It is gas filled and that is how the bulb was burning in horizontal position from here.

Pretty, please no more Chinese failure.