Last comments - fluorescent ballasts and starters

Last comments - fluorescent ballasts and starters

IMG_20200206_161149.jpg
Vintage_Philips_Fs4_starter_pure_argon.jpg
vintage sylvania fs4.jpg
Experimental_starter_glowbotle_argon_pure.jpg
Experimental_starter_glowbotle_argon_pure.jpg
NOS (but baldy beaten up) Soviet preheat Fluorescent ballasts for F40T12 tubes. Rated at 230Vvytautas_lamps02/06/20 at 11:13rjluna2: Wow Vintage Philips FS (S) 10 fluorescent starter pure argon filled.vytautas_lamps01/05/20 at 12:02adamrvlx: You know what mixture of gases you get when you lo... Vintage Sylvania FS-4 fluorescent starters (Click on image to enlarge for detailed look)vytautas_lamps12/19/19 at 05:50vytautas_lamps: My city also have two abandoned soviet dairy facto... Experimental Sylvania glowbottle for HID starting, pure argon fill.vytautas_lamps11/13/19 at 00:28tolivac: I have a 400W Eye MH 6000K lamp that uses a neon f... Experimental Sylvania glowbottle for HID starting, pure argon fill.vytautas_lamps11/13/19 at 00:24James: Hydrogen is included in nearly all starters, becau...
Experimental_starter_glowbotle_argon_pure.jpg
Experimental_starter_glowbotle_argon_pure.jpg
Experimental_glowbottle_starter_pure_neon.jpg
Experimental_starter_glowbotle_argon_pure.jpg
IMG_20191103_210146.jpg
Experimental Sylvania glowbottle for HID starting, pure argon fill.vytautas_lamps11/13/19 at 00:09Alex: Hydrogen needs Oxygen for an exothermic reaction .... Experimental Sylvania glowbottle for HID starting, pure argon fill.vytautas_lamps11/12/19 at 23:58dor123: How it contains hydrogen, if this is an explosive ... Experimental Sylvania glowbottle for HID starting, pure neon fill.vytautas_lamps11/12/19 at 16:09James: In fact it is filled with 75% neon, 19% argon and ... Experimental Sylvania glowbottle for HID starting, pure argon fill.vytautas_lamps11/12/19 at 16:07James: I just looked up the gas filling of this starter. ... Soviet made vintage fluorescent ballast from 1962!!!vytautas_lamps11/05/19 at 02:07vytautas_lamps: Yep! I was very sad when I rewired it for test run...
IMG_20191103_210146.jpg
IMG_20191103_210146.jpg
IMG_20191103_210146.jpg
Seymour_FS85_T17_tube_starter_pure_neon.jpg
Vintage_Philips_Fs4_starter_pure_argon.jpg
Soviet made vintage fluorescent ballast from 1962!!!vytautas_lamps11/04/19 at 22:57silverliner: Glad you figured out the correct wiring! Yeah, it ... Soviet made vintage fluorescent ballast from 1962!!!vytautas_lamps11/04/19 at 13:58vytautas_lamps: Thanks! Will do some experimenting with this balla... Soviet made vintage fluorescent ballast from 1962!!!vytautas_lamps11/03/19 at 15:06fluorescent lover 40: Cool find! Bigger case Fluorescent starter for T17 fluorescent tubes pure neon fillvytautas_lamps10/21/19 at 16:11ramdude2014: Pass & Seymour inc. There a Syracuse New York ... Vintage Philips FS (S) 10 fluorescent starter pure argon filled.vytautas_lamps10/08/19 at 16:34Jovan: So these starters were radiating @ 3.6 Roentgen ?
Vintage_Philips_Fs4_starter_pure_argon.jpg
Vintage_Philips_Fs4_starter_pure_argon.jpg
Vintage_Philips_Fs4_starter_pure_argon.jpg
Experimental_starter_glowbotle_argon_pure.jpg
Experimental_glowbottle_starter_pure_neon.jpg
Vintage Philips FS (S) 10 fluorescent starter pure argon filled.vytautas_lamps10/04/19 at 11:05James: That is a good question which I cannot answer prop... Vintage Philips FS (S) 10 fluorescent starter pure argon filled.vytautas_lamps10/04/19 at 10:36Ash: Is there any significant percent of it (vs. the Hy... Vintage Philips FS (S) 10 fluorescent starter pure argon filled.vytautas_lamps10/04/19 at 10:07rjluna2: @James: Does the Tritium gas have different discha... Experimental Sylvania glowbottle for HID starting, pure argon fill.vytautas_lamps10/04/19 at 08:19James: Again this is a Philips Terneuzen glowbottle, but ... Experimental Sylvania glowbottle for HID starting, pure neon fill.vytautas_lamps10/04/19 at 08:14James: If I am not mistaken, this one is actually Neon-kr...
Seymour_FS85_T17_tube_starter_pure_neon.jpg
GEC_startrs_FS_4___FS_2.jpg
Sylvania_FS2_glowbottle_1990s_argon_xenon_filled.jpg
Sylvania_FS11_Starter_pure_helium.jpg
Vintage_OSRAM_made_in_England_pure_argon.jpg
Bigger case Fluorescent starter for T17 fluorescent tubes pure neon fillvytautas_lamps10/04/19 at 08:06James: I think the metal starters disappeared in EU in th... GEC made in UK FS4 and FS2 vytautas_lamps10/04/19 at 07:52James: GEC stopped making starters long ago, so the top o... Sylvania vinatge NOS FS2 1990s glowbottle.vytautas_lamps10/04/19 at 07:50James: This is quite an interesting glowbottle because of... Sylvania FS11 starter with pure helium filling.vytautas_lamps10/04/19 at 07:45James: It may well be helium filled, but it definitely al... Vintage rare OSRAM made in UK starter. Filled with argon.vytautas_lamps10/04/19 at 07:28James: There seems to be some kind of white coating insid...
Vintage_Philips_Fs4_starter_pure_argon.jpg
Wotan_FS2_sstarter_argon_xenon_fill.jpg
Vintage_Philips_Fs4_starter_pure_argon.jpg
Vintage_Philips_Fs4_starter_pure_argon.jpg
Vintage_Philips_Fs4_starter_pure_argon.jpg
Vintage Philips FS (S) 10 fluorescent starter pure argon filled.vytautas_lamps10/04/19 at 07:26James: Interesting about the glow colour, I had not notic... Wotan FS-2 series fluorescent starter xenon argon filledvytautas_lamps10/04/19 at 07:16James: This one is probably from late 1980s, I can rememb... Vintage Philips FS (S) 10 fluorescent starter pure argon filled.vytautas_lamps10/03/19 at 20:58Binarix128: I have one of this starters but with a normal gas ... Vintage Philips FS (S) 10 fluorescent starter pure argon filled.vytautas_lamps10/03/19 at 20:57Binarix128: Cool! I think these starters are hard to find. Vintage Philips FS (S) 10 fluorescent starter pure argon filled.vytautas_lamps10/03/19 at 20:30fluorescent lover 40: Nice!
136 files on 5 page(s) 1
© 2005-2020 Lighting-Gallery.net | Powered by: Coppermine Photo Gallery